Our Laboratory
Our Laboratory
INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROSCOPY ASTM D4951
This test method covers the quantitative determination of barium, boron, calcium, copper, magnesium, molybdenum, phosphorous, sulfur, and zinc in unused lubricating oils and additive packages. This test method usually requires several minutes per sample. This test method covers eight elements and thus provides more elemental composition data. This test method can be used to determine if additive packages and unused lubricating oils meet specifications with respect to elemental composition. A sample portion is weighed and diluted by mass with mixed xylenes. An internal standard, which is required, is either weighed separately into the test solution or is previously combined with the dilution solvent. Calibration standards are prepared similarly. The solutions are introduced to the ICP instrument by free aspiration or an optional peristaltic pump. By comparing emission intensities of elements in the test specimen with emission intensities measured with the calibrated standards and by applying the appropriate internal standard correction, the concentrations of elements in the sample are calculable.
Fourier Transformer Infrared Spectroscopy 65
FTIR can measure the amount of infrared light absorbed at particular wavelengths, develop a ‘spectra’ for the entire infrared wavelength range of how much infrared light was absorbed at what wavelength, and compare that against known standards in a library or against a baseline spectra. On-site FTIR also provides incoming oil quality assurance/quality control, in-service oil analysis and root cause analysis. Basically the FTIR method of Infrared analysis is a quicker and more accurate measurement of Infrared Analysis than the original IR method of analysis.
Cold Cranking Simulator (Ccs) Astm D 5293 And Sae J300.
Cold-Cranking Simulator (CSS) measure the apparent viscosity of oils at temperatures from –35°C to –5°C within a viscosity range of 900 mPa·s to 25,000 mPa·s. It combines automatic sample loading, computer-controlled operation, and solvent-free cleaning to permit completely unattended operation. No further operator involvement is required after initial loading of the sample table and identification of samples. The CCS- automatically test up to 30 samples at one time, calculate their viscosities, and record the results, freeing the operator for other tasks. Improved temperature management of the rotor/stator eliminates the need for grouping the samples by temperature of analysis, as was necessary in older CCS models. In addition, a thermoelectric sample warming cycle greatly improves the sample flushing process. The CCS meets all the requirements of ASTM D 5293 and SAE J300.
Four Ball Machine Astm D2266 & Astm D2596
ASTM 2596 test method covers the determination of the load carrying properties of lubricating greases. Two determinations are made Load –Wear Index (formerly called Mean-Hertz Load) and Weld Point, by means of the Four-Ball Extreme pressure (EP) Tester. The tester is operated with one steel balls held stationary in the form of a cradle. The rotating speed is 1770 rpm. Lubricating greases are brought to 27⁰C and then subjected to a series of tests of 10-s duration at increasing loads until welding occurs.
ASTM 2266 test method can be used to determine the relative wear-preventing properties of greases under the test conditions and if the test conditions are changed the relative ratings may be different. This test method cannot be used to differentiate between Extreme Pressure (EP) and Non Extreme Pressure (Non-EP) Greases.
Flash Point Astm D92
This test method describes the determination of the flash point and fire point of petroleum products by an Automated Cleveland Open Cup apparatus .This is applicable to all petroleum products with the flash points above 79°C and below 400°C except fuel oils.
Sample filled into a test cup. The temperature of the test specimen increased rapidly at first and then at a slower constant rate as the flash point is approached at specified intervals, a test flame is passed across the cup. The flash point is the lowest liquid temperature at which application of the testflam causes the vapors of the test specimen of the sample to ignite.